Skip to Content
Home

Slab Insulation

The RTF is a technical advisory committee to the Northwest Power and Conservation Council established in 1999 to develop standards to verify and evaluate energy efficiency savings

NWCouncil.org Contact
Calendar
Work products
UES Measures Standard protocols list Demand Response Technologies Supporting Documents Propose a measure or standard protocol Proposed measures and status Whole Building Efforts
Subcommittees
  • Commercial HVAC
  • Connected Thermostats
  • Demand Response
  • Duct Sealing
  • Guidelines
  • Heat Pump Water Heaters
  • Implementers Group
  • Modeling
  • Natural Gas
  • New Homes
  • Non-Residential Lighting
  • Operations
  • Refrigeration
  • Research and Evaluation
  • Residential HVAC
  • RTF Policy Advisory Committee
  • Small and Rural Utilities
  • Weatherization
  • Whole Building
Home Calendar News and updates Decisions Guidelines

About the RTF

  • RTF Membership - 2025-2027
  • Work plan and budget
  • Request for proposals
  • Charter and bylaws
  • Conflict of interest policy
  • RTF Policy Advisory Committee
  • Contacts
  • Conservation achievements

Work Products

UES Measures Standard protocols list Demand Response Technologies Supporting Documents Propose a measure or standard protocol Proposed measures and status Whole Building Efforts

Subcommittees

  • Commercial HVAC
  • Connected Thermostats
  • Demand Response
  • Duct Sealing
  • Guidelines
  • Heat Pump Water Heaters
  • Implementers Group
  • Modeling
  • Natural Gas
  • New Homes
  • Non-Residential Lighting
  • Operations
  • Refrigeration
  • Research and Evaluation
  • Residential HVAC
  • RTF Policy Advisory Committee
  • Small and Rural Utilities
  • Weatherization
  • Whole Building
Close Navigation
  1. /

UES Measure

  • Slab Insulation

Slab Insulation

At a Glance

Category 
none
Status 
deactivated
Sector 
residential
Applications 
new construction

Workbook

Latest Version

ResNewSFSlabInsulation_v3_2.xlsm

File ResNewSFSlabInsulation_v3_2.xlsm
QC review complete.
Date 
Dec 5, 2016
Version number 
3.2

Past Versions

version date document
3.1
May 20, 2016
File ResNewSFSlabInsulation_v3_1.xlsm
Updated to 7th Plan format and assumptions. Currently undergoing QC. Associated SEEM Workbook.
3.0
Apr 29, 2016
File ResNewSFSlabInsulation_v3.xlsm
Currently Undergoing QC
2.9
Jan 04, 2016
File ResNewSFSlabInsulation_v2_9.xlsm
Delivery verification checklist added
2.8
Jul 29, 2014
File ResNewSFSlabInsulation_v2_8.xlsm
QC Review complete
2.6
Jun 06, 2014
File ResNewSFSlabInsulation_v2_6.xlsm
Updated as per recommendation memo. Currently undergoing QC.
1.3
Dec 11, 2012
File ResNewSFSlabInsulation_v1_3.xlsx
Summary sheet added.
1.2
May 12, 2010
File FullSlabR10_FY10v1_2.xls
Original savings workbook.
Supporting Documents
File ResNewSFSlabInsulation_RecommendationMemo.docx
File SlabInsulation SEEM Runs.xlsm

Decisions

Expand All Decisions

Latest decision

Decision details

Decided 
April 23, 2019
RTF Meeting: April 23, 2019

Deactivate Measure

Decision Details

Deactivate Slab Insulation UES.

Decided 
April 19, 2016
RTF Meeting: April 19, 2016

Approve measure update

Decision Details

Adopt the New Construction Slab Insulation measure analysis and:•Change Measure Status to 'Small Saver'•Keep Measure Category as 'Active'•Change Sunset Date to April 30, 2019

Decided 
September 22, 2015
RTF Meeting: September 22, 2015

Approve measure update

Decision Details

Adopt the delivery verification guidance, and related specification refinements, as presented for the following measures:

  • Agricultural Irrigation Hardware
  • Agricultural Lighting – Area Lights
  • Agricultural Stock Watering Tanks
  • Agricultural Variable Frequency Drives – Potato/Onion Shed;
  • Commercial Appliances – Clothes Washers
  • Commercial Cooking Equipment – Combination Ovens
  • Commercial Cooking Equipment – Convection Ovens
  • Commercial Cooking Equipment – Fryers
  • Commercial Cooking Equipment – Hot Food Holding Cabinets
  • Commercial Cooking Equipment – Pre-Rinse Spray Valves
  • Commercial Cooking Equipment – Steamers
  • Commercial DHW – Efficient Tanks
  • Commercial DHW – Showerheads
  • Commercial Grocery – Anti-sweat Heater Controls
  • Residential Heating/Cooling – DHP for FAF in SF and MH
  • Residential Heating/Cooling – DHP for Zonal Heat MH
  • Residential New Construction – Slab Insulation
Decided 
March 18, 2014
RTF Meeting: March 18, 2014

Approve measure update

Decision Details

Approve the Residential New Construction Slab Insulation measure as a 'Proven' UES; Set the measure status to ‘Active;’ and Set the sunset date to December 31, 2016.

Decided 
December 17, 2013
RTF Meeting: December 17, 2013

Sunset date extension

Decision Details

Extend the sunset date until April, 2014 in order to give time for a calibration of New Construction measures in SEEM.

Decided 
December 11, 2012
RTF Meeting: December 11, 2012

Set measure to Under Review

Decision Details

Adopt the SBW recommendations for the Residential Single Family New Construction Slab Insulation UES measure and change the status to Under Review with a sunset date of December 31, 2013.

RTF staff will work to update the measure per the recommendation memo and seek RTF approval for "Active" status by the sunset date.

Small/rural Checklist

Latest Version

SlabInsulation_SRR_Checklist.xlsx

File SlabInsulation_SRR_Checklist.xlsx
Date 
Apr 29, 2016

Past Versions

version date document
Jul 07, 2014
File ResSlabInsulationNC_SRR_Checklist.xlsx